Accutronics Reverb Tank 4EB3C1B
Accutronics Reverb Tank 4EB3C1B
Preview: Accutronics Reverb Tank 4EB3C1B
Preview: Accutronics Reverb Tank 4EB3C1B
Accutronics Reverb Tank 4EB3C1B
Mobile Preview: Accutronics Reverb Tank 4EB3C1B
Mobile Preview: Accutronics Reverb Tank 4EB3C1B

Accutronics Reverb Tank 4EB3C1B

Product No.:
ra4eb3c1b
In stock for immediate delivery. Delivery time depends on the destination country* In stock for immediate delivery. Delivery time depends on the destination country*
RoHs:
conform
Weight:
0.68 kg per piece
28,00 €

incl. VAT excl. Shipping costs

Recommended products:

Rubber Grommet for Reverb Tank, 4 pcs
  • Rubber grommets for reverb tanks, package of four.
  • Mounting Hole Diameter = 3/8"
  • Outer Diameter = 1/2"
1,70 €

Customers who bought this product bought also the following products:

Sovtek 5881 - PAIR

2 tubes, matched as pair

The Sovtek 5881 delivers a warm, round tone that "sweetens" any vintage or modern guitar amp design. Chances are if an amp uses 6L6-style output tubes, it has Sovtek 5881's in its sockets. Built to rigid military standards, the 5881 will tolerate higher voltages than any other 6L6. In fact, they're frequently used as replacements for the old 7027 model in vintage Ampegs.

51,00 €
25,50 € per Piece

Rubber Grommet for Reverb Tank, 4 pcs
  • Rubber grommets for reverb tanks, package of four.
  • Mounting Hole Diameter = 3/8"
  • Outer Diameter = 1/2"
1,70 €

Tube-Town Reverb Tank RCA cable, 48" (120 cm)
  • Reverb Tank RCA cable
  • ca. 48" (120 cm)
  • Right-Angle plugs
  • Replaces Fender Reverb-Tank RCA cable
1,95 €

F+T 50 + 50 µF / 500 V Multisection
  • Type: Multisection Capacitor
  • Capacitance: 50 + 50 µF
  • Voltage Rating: 500 V
  • Tolerance: - 10% / +30 %
  • Operating Temperature Range: - 40°C / + 85 °C
  • Dimensions: Ø 35 mm x 50 mm
  • Termination Style: radial, solder lugs
9,80 €

Elektrolyt 100 µF @ 16V
  • Type: Electrolytic can capacitor
  • Capacitance: 100 µF
  • Voltage Rating: 16 V
  • Tolerance: - 20 % / +20 %
  • Operating Temperature Range: - 40°C / + 105 °C
  • Dimensions: Ø 6 mm x 11 mm
  • Termination Style: radial
  • Grid: 2,5

Images are for reference only. See Product Specifications

0,19 €

Elektrolyt 47 µF @ 63V
  • Type: Electrolytic can capacitor
  • Capacitance: 47 µF
  • Voltage Rating: 63 V
  • Tolerance: - 20 % / +20 %
  • Operating Temperature Range: - 40°C / + 105 °C
  • Dimensions: Ø 8 mm x 11 mm
  • Termination Style: radial
  • Grid: 3,5

Images are for reference only. See Product Specifications

0,14 €

Elektrolyt 220 µF @ 35V
  • Type: Electrolytic can capacitor
  • Capacitance: 220 µF
  • Voltage Rating: 35 V
  • Tolerance: - 20 % / +20 %
  • Operating Temperature Range: - 40°C / + 85 °C
  • Dimensions: Ø 10 mm x 12 mm
  • Termination Style: radial
  • Grid: 5

Images are for reference only. See Product Specifications

0,18 €

Probe Bias Octal, assembled
Bias probe for indirect measurement of quiescent bias current of a tube. The adapter is inserted between the tube and the socket and gets connected to a standard voltmeter (not included). Pay attention to the quality of the measuring device and sufficiently charged batteries!

The quiescent current is measured indirectly via a precision resistor integrated in the adapter. The advantages of this measuring method are harmless voltages at the measuring plugs, which are in the mV range, as well as short ways for the current, since it does not need to be fed through the measuring device (common practice with many measuring adapters of Far Eastern production). As a result, there is no risk of oscillations of the amplifier which can lead to possible damage of the tubes or the amplifier itself.

Note: This adapter cannot be used when additional tube brackets are installed. These must be removed before using the measurement adapter and reattached after the measurement is complete.

Procedure for the measurement

Determine the resistance of the adapter, including the measuring leads. To do this, connect the adapter to the meter, but do not plug it between the tubes and the amplifier, yet. Select the measuring range “Ohm” on the meter and note the measured value, e.g. 1,1 ohms.

For the final measurement insert the adapter between the tube and the currentless amplifier and connect it to the meter, select the measuring range mV and switch on the amplifier. When the amplifier has reached a stable operating condition, read the value in mV from the meter and calculate the quiescent current based on Ohm's law.

Example:
measured voltage = 47 mV, resistance of the adapter = 1,1 ohms.
Formula (I = U / R) or in this case:
bias current (in A) = measured value (voltage in V) / measured value (resistance in ohm)
0.047V / 1.1 ohms = 0.042A or 42mA respectively

For the calculation of the correct bias current as well as further information on the bias measurement, please refer to further documents or the bias setting instructions in the info area, as well as the manual of the amplifier itself.

This measuring adapter is suitable for all EL34, 6L6, 6550, KT88, 6V6, 6CA7 and other tubes with the same pin layout.

Attention high Voltage! Measurements and work on tube amplifiers should only be carried out by qualified persons.