Tube-Town Reverb Tank RCA cable, 48" (120 cm)
Tube-Town Reverb Tank RCA cable, 48" (120 cm)

Tube-Town Reverb Tank RCA cable, 48" (120 cm)

Product No.:
ttca-rca01
In stock. Delivery time depends on the destination country* In stock. Delivery time depends on the destination country*
RoHs:
conform
Weight:
0.045 kg per piece
1,95 €

incl. VAT excl. Shipping costs

Needed for:

Customers who bought this product bought also the following products:

Kit Seriel FX-Loop LND150

Active, serial FX-Loop for a subsequent installation in an existing tube amplifier
The FX-Loop works with  two LND150 in the send and in the return stage. The send and return level can be adjusted to their optimal value with two potentiometers. The Loop works with the present high voltage of the amplifier.
It has two inputs for low and high signal levels.

Input Levels:
InA: 30 - 60 Vpp, max. 65 Vpp
InB: 10 - 15 Vpp, max. 18 Vpp

The FX-Loop utilize POTENTIALLY FATAL HIGH VOLTAGES.
Seek help from a competent technician if you are in any way unfamiliar with high voltage circuits.
Use at your own risk.

Files:

27,80 €
Probe Bias Octal, assembled
Bias probe for indirect measurement of quiescent bias current of a tube. The adapter is inserted between the tube and the socket and gets connected to a standard voltmeter (not included). Pay attention to the quality of the measuring device and sufficiently charged batteries!

The quiescent current is measured indirectly via a precision resistor integrated in the adapter. The advantages of this measuring method are harmless voltages at the measuring plugs, which are in the mV range, as well as short ways for the current, since it does not need to be fed through the measuring device (common practice with many measuring adapters of Far Eastern production). As a result, there is no risk of oscillations of the amplifier which can lead to possible damage of the tubes or the amplifier itself.

Note: This adapter cannot be used when additional tube brackets are installed. These must be removed before using the measurement adapter and reattached after the measurement is complete.

Procedure for the measurement

Determine the resistance of the adapter, including the measuring leads. To do this, connect the adapter to the meter, but do not plug it between the tubes and the amplifier, yet. Select the measuring range “Ohm” on the meter and note the measured value, e.g. 1,1 ohms.

For the final measurement insert the adapter between the tube and the currentless amplifier and connect it to the meter, select the measuring range mV and switch on the amplifier. When the amplifier has reached a stable operating condition, read the value in mV from the meter and calculate the quiescent current based on Ohm's law.

Example:
measured voltage = 47 mV, resistance of the adapter = 1,1 ohms.
Formula (I = U / R) or in this case:
bias current (in A) = measured value (voltage in V) / measured value (resistance in ohm)
0.047V / 1.1 ohms = 0.042A or 42mA respectively

For the calculation of the correct bias current as well as further information on the bias measurement, please refer to further documents or the bias setting instructions in the info area, as well as the manual of the amplifier itself.

This measuring adapter is suitable for all EL34, 6L6, 6550, KT88, 6V6, 6CA7 and other tubes with the same pin layout.

Attention high Voltage! Measurements and work on tube amplifiers should only be carried out by qualified persons.
26,90 €
Tube-Town Reverb Tank Bag 17", Black
  • Bag for Reverb Tank, Size: 17"  (43cm),
  • Black Tolex
  • Made in Germany
     
13,95 €
Fender Chassis-Straps Medium
  • Mounting hole distance around 101 mm
  • Medium Chrome straps
  • length around 4-5/8" (11.7 cm) end to end
  • mounting screws included
  • For '65 Deluxe, Super, '63 Vibroverb and Vibrolux®
13,95 €
Mallory 150's 0,047 µF / 630 VDC
Mallory Type 150 is a general purpose capacitor for use in blocking, bypass, decoupling, smoothing and some timing applications.
  • Epoxy end fill meets UL94V-0
  • Non inductively wound
  • Flame retardant outer wrap meets UL510
  • Non polar
Specifications:
  • Operating Tempeature Range: –55 ºC to +125 ºC (derate linearly to 50% rated voltage at 125 ºC)
  • Dielectric Withstand Voltage: .6 x rated voltage for 2 s @ +25 ºC ±5 ºC
  • Dissipation Factor (DF): tgd x 10–4 at +25 ºC ±5 ºC
  • Insulation Resistance: 10,000 MO x µF, 30,000 MO Min.
  • Self Inductance: 1 nH max. per 1 mm lead and body length
  • Life Test: 1000 hrs @ 85 ºC 1.25 x Vn
  • Damp Heat Test: 95% RH @ +45 ºC for 21 days
  • Soldering: 260 ºC ±5 ºC for 10 s ±1 s
  • Long Term Storage Stability: ?C/C = ±3% after 2 years
2,65 €
Mallory 150's 0,047 µF / 250 V DC
Mallory Type 150 is a general purpose capacitor for use in blocking, bypass, decoupling, smoothing and some timing applications.
  • Epoxy end fill meets UL94V-0
  • Non inductively wound
  • Flame retardant outer wrap meets UL510
  • Non polar
Specifications:
  • Operating Tempeature Range: –55 ºC to +125 ºC (derate linearly to 50% rated voltage at 125 ºC)
  • Dielectric Withstand Voltage: .6 x rated voltage for 2 s @ +25 ºC ±5 ºC
  • Dissipation Factor (DF): tgd x 10–4 at +25 ºC ±5 ºC
  • Insulation Resistance: 10,000 MO x µF, 30,000 MO Min.
  • Self Inductance: 1 nH max. per 1 mm lead and body length
  • Life Test: 1000 hrs @ 85 ºC 1.25 x Vn
  • Damp Heat Test: 95% RH @ +45 ºC for 21 days
  • Soldering: 260 ºC ±5 ºC for 10 s ±1 s
  • Long Term Storage Stability: ?C/C = ±3% after 2 years
1,10 €
Rubber foot with steel insert 30 x 15 mm  - Pack of 4
  • Rubber foot with steel insert
  • Size: d = 30 mm,  h = 15 mm
  • Pack of 4
  • Screws included
2,05 €
0,51 € per Pack
Jack 6,3 mm, Mono, Chassis-Mount
Jack 6,3 mm, Mono, Chassis-Mount
0,50 €